Chemical Compatibility

Lindol Hydraulic Fluid, Phosphate Ester Type vs 13 elastomers

Best choices for Lindol Hydraulic Fluid, Phosphate Ester Type: FFKM, EPDM, IIR, FEPM. Full ratings below, A is continuous-service suitable, D is not recommended.

Lindol Hydraulic Fluid, Phosphate Ester Type
FFKM, EPDM, IIRBest choices
NBR, HNBR, CRAvoid
ElastomerRatingMeaning
NBR Nitrile (Buna-N)DNot recommended
HNBR Hydrogenated NitrileDNot recommended
FKM Fluorocarbon (Viton)BGood, minor effect
FFKM PerfluoroelastomerAExcellent, continuous service
EPDM Ethylene PropyleneAExcellent, continuous service
VMQ SiliconeCConditional, test first
FVMQ FluorosiliconeCConditional, test first
CR Neoprene (Chloroprene)DNot recommended
NR Natural RubberDNot recommended
SBR Styrene ButadieneDNot recommended
IIR ButylAExcellent, continuous service
AU PolyurethaneDNot recommended
FEPM Aflas (TFE/P)AExcellent, continuous service

Room-temperature, neat chemical unless stated. Concentration and temperature shift ratings, validate with our lab.

Ratings are for the neat chemical at room temperature unless stated; concentration and temperature change everything. Validate with our lab before committing a compound. Search another chemical → More chemicals starting with L →

Sealing against Lindol Hydraulic Fluid, Phosphate Ester Type?

Tell us concentration, temperature and duty, we will recommend and sample the compound.